docs: Add a G-Codes.md file with the list of available commands
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
		
							
								
								
									
										114
									
								
								docs/G-Codes.md
									
									
									
									
									
										Normal file
									
								
							
							
						
						
									
										114
									
								
								docs/G-Codes.md
									
									
									
									
									
										Normal file
									
								
							| @@ -0,0 +1,114 @@ | ||||
| This document describes the commands that Klipper supports. These are | ||||
| commands that one may enter into the OctoPrint terminal tab. | ||||
|  | ||||
| # G-Code commands | ||||
|  | ||||
| Klipper supports the following standard G-Code commands: | ||||
| - Move (G0 or G1): `G1 [X<pos>] [Y<pos>] [Z<pos>] [E<pos>] [F<speed>]` | ||||
| - Dwell: `G4 P<milliseconds>` | ||||
| - Move to origin: `G28 [X] [Y] [Z]` | ||||
| - Turn off motors: `M18` or `M84` | ||||
| - Wait for current moves to finish: `M400` | ||||
| - Use absolute/relative distances for extrusion: `M82`, `M83` | ||||
| - Use absolute/relative coordinates: `G90`, `G91` | ||||
| - Set position: `G92 [X<pos>] [Y<pos>] [Z<pos>] [E<pos>]` | ||||
| - Set speed factor override percentage: `M220 S<speed>` | ||||
| - Set extrude factor override percentage: `M221 S<percent>` | ||||
| - Get extruder temperature: `M105` | ||||
| - Set extruder temperature: `M104 [T<index>] [S<temperature>]` | ||||
| - Set extruder temperature and wait: `M109 [T<index>] S<temperature>` | ||||
| - Set bed temperature: `M140 [S<temperature>]` | ||||
| - Set bed temperature and wait: `M190 S<temperature>` | ||||
| - Set fan speed: `M106 S<value>` | ||||
| - Turn fan off: `M107` | ||||
| - Emergency stop: `M112` | ||||
| - Get current position: `M114` | ||||
| - Get firmware version: `M115` | ||||
| - Set home offset: `M206 [X<pos>] [Y<pos>] [Z<pos>]` | ||||
| - Run PID tuning: `M303 [E<index>] S<temperature>` | ||||
|  | ||||
| For further details on the above commands see the | ||||
| [RepRap G-Code documentation](http://reprap.org/wiki/G-code). | ||||
|  | ||||
| Klipper's goal is to support the G-Code commands produced by common | ||||
| 3rd party software (eg, OctoPrint, Printrun, Slic3r, Cura, etc.) in | ||||
| their standard configurations. It is not a goal to support every | ||||
| possible G-Code command. Instead, Klipper prefers human readable | ||||
| ["extended G-Code commands"](#extended-g-code-commands). | ||||
|  | ||||
| ## G-Code SD card commands | ||||
|  | ||||
| Klipper also supports the following standard G-Code commands if the | ||||
| "virtual_sdcard" config section is enabled: | ||||
| - List SD card: `M20` | ||||
| - Initialize SD card: `M21` | ||||
| - Select SD file: `M23 <filename>` | ||||
| - Start/resume SD print: `M24` | ||||
| - Pause SD print: `M25` | ||||
| - Set SD position: `M26 S<offset>` | ||||
| - Report SD print status: `M27` | ||||
|  | ||||
| # Extended G-Code Commands | ||||
|  | ||||
| Klipper uses "extended" G-Code commands for general configuration and | ||||
| status.  These extended commands all follow a similar format - they | ||||
| start with a command name and may be followed by one or more | ||||
| parameters. For example: `SET_SERVO SERVO=myservo ANGLE=5.3`. In this | ||||
| document, the commands and parameters are shown in uppercase, however | ||||
| they are not case sensitive. (So, "SET_SERVO" and "set_servo" both run | ||||
| the same command.) | ||||
|  | ||||
| The following standard commands are supported: | ||||
| - `QUERY_ENDSTOPS`: Probe the axis endstops and report if they are | ||||
|   "triggered" or in an "open" state. This command is typically used to | ||||
|   verify that an endstop is working correctly. | ||||
| - `RESTART`: This will cause the host software to reload its config | ||||
|   and perform an internal reset. This command will not clear error | ||||
|   state from the micro-controller (see FIRMWARE_RESTART) nor will it | ||||
|   load new software (see | ||||
|   [the FAQ](FAQ.md#how-do-i-upgrade-to-the-latest-software)). | ||||
| - `FIRMWARE_RESTART`: This is similar to a RESTART command, but it | ||||
|   also clears any error state from the micro-controller. | ||||
| - `STATUS`: Report the Klipper host software status. | ||||
| - `HELP`: Report the list of available extended G-Code commands. | ||||
|  | ||||
| ## Custom Pin Commands | ||||
|  | ||||
| The following command is available when a "digital_output" or | ||||
| "pwm_output" config section is enabled: | ||||
| - `SET_PIN PIN=config_name VALUE=<value>` | ||||
|  | ||||
| ## Servo Commands | ||||
|  | ||||
| The following commands are available when a "servo" config section is | ||||
| enabled: | ||||
| - `SET_SERVO SERVO=config_name WIDTH=<seconds>` | ||||
| - `SET_SERVO SERVO=config_name ANGLE=<degrees>` | ||||
|  | ||||
| ## Probe | ||||
|  | ||||
| The following commands are available when a "probe" config section is | ||||
| enabled: | ||||
| - `PROBE`: Move the nozzle downwards until the probe triggers. | ||||
| - `QUERY_PROBE`: Report the current status of the probe ("triggered" | ||||
|   or "open"). | ||||
|  | ||||
| ## Delta Calibration | ||||
|  | ||||
| The following commands are available when the "delta_calibrate" config | ||||
| section is enabled: | ||||
| - `DELTA_CALIBRATE`: This command will probe seven points on the bed | ||||
|   and recommend updated endstop positions, tower angles, and radius. | ||||
|   - `NEXT`: If manual bed probing is enabled, then one can use this | ||||
|     command to move to the next probing point during a DELTA_CALIBRATE | ||||
|     operation. | ||||
|  | ||||
| ## Bed Tilt | ||||
|  | ||||
| The following commands are available when the "bed_tilt" config | ||||
| section is enabled: | ||||
| - `BED_TILT_CALIBRATE`: This command will probe the points specified | ||||
|   in the config and then recommend updated x and y tilt adjustments. | ||||
|   - `NEXT`: If manual bed probing is enabled, then one can use this | ||||
|     command to move to the next probing point during a | ||||
|     BED_TILT_CALIBRATE operation. | ||||
| @@ -16,7 +16,8 @@ on tuning the pressure advance config. | ||||
|  | ||||
| The [kinematics](Kinematics.md) document provides some technical | ||||
| details on how Klipper implements motion. The [FAQ](FAQ.md) answers | ||||
| some common questions. | ||||
| some common questions. The [G-Codes](G-Codes.md) document lists | ||||
| currently supported run-time commands. | ||||
|  | ||||
| The history of Klipper releases is available at | ||||
| [releases](Releases.md). See [contact](Contact.md) for information on | ||||
|   | ||||
		Reference in New Issue
	