EMC optimisations

-eth shield is not connected to the GND rather it shields "input" of poe
-used smaller package for bulk PoE capacitor
-Changed common mode filter to Pulse T8113
-Added more inductor filters on the primary side
-replaced secondary side ferrite silter with an inductor
-used distributed "flyback" capacitor (3 instead of 1)
-slightly increased distance between the poe transformer and the
ethernet signal traces
- extended GND1 under the transformer
- primary snubber circuit is now in "hot-loop" area
-repositioned poe enable optocoupler

Signed-off-by: Dominik Sliwa <dominik@sliwa.io>