EMC optimisations

-eth shield is not connected to the GND rather it shields "input" of poe
-used smaller package for bulk PoE capacitor
-Changed common mode filter to Pulse T8113
-Added more inductor filters on the primary side
-replaced secondary side ferrite silter with an inductor
-used distributed "flyback" capacitor (3 instead of 1)
-slightly increased distance between the poe transformer and the
ethernet signal traces
- extended GND1 under the transformer
- primary snubber circuit is now in "hot-loop" area
-repositioned poe enable optocoupler

Signed-off-by: Dominik Sliwa <dominik@sliwa.io>
This commit is contained in:
Dominik Sliwa
2022-07-25 01:29:09 +02:00
parent a60829b4cf
commit f6dc839e95
9 changed files with 19053 additions and 13152 deletions

View File

@@ -1,6 +1,6 @@
{
"board": {
"active_layer": 0,
"active_layer": 37,
"active_layer_preset": "",
"auto_track_width": false,
"hidden_nets": [],
@@ -63,7 +63,7 @@
35,
36
],
"visible_layers": "fffffff_ffffffff",
"visible_layers": "ffffff0_ffffffff",
"zone_display_mode": 0
},
"meta": {